ãã€ãŸã§ããã«ã¿ã«ã
é è¿äž¡çšã³ã³ã¿ã¯ãããã€ãã€Â®ïž
幎霢ã«ããèŠãæ¹ã®å€åã«åãããŠã
ãã¹ãŠã®è·é¢ã§å¿«é©ãªèŠãæ¹ãžãâ»1
å¶ããã®ã¯ãç¬èªã®ã¬ã³ãºãã¶ã€ã³
Binocular Progressive System⢠ãããã¥ã©ãŒ ããã°ã¬ãã·ã ã·ã¹ãã
èŠããè·é¢ã«åãããŠãå¿«é©ãªèŠçãã
ãã€ãã€Â® ãã«ããã©ãŒã«ã«ã¯ãç¬èªã®æè¡ããããã¥ã©ãŒ ããã°ã¬ãã·ã ã·ã¹ãã ããæ¡çšãæ £ãããããå¿«é©ãªèŠãæ¹ããµããŒãããŸãã
äºå®ããã€ãã€Â® ãã«ããã©ãŒã«ã«ã
è£
çšããå€ãã®ãŠãŒã¶ãŒãæºè¶³ãããŠããŸãã
å
šäœçãª
èŠãæ¹ã«æºè¶³â»1
ã¢ã¯ãã£ããªæ¯æ¥ã
éãããšãã§ããâ»3
1æ¥ãéããŠå¿«é©
ãªèŠãæ¹ãâ»3
ãã€ãŸã§ãç¶ãèªç¶ãªããããã
ã¢ã¯ã¢ãã©ãŒã ãã¯ãããžãŒã
ã¢ã¯ã¢ãã©ãŒã ® ãã¯ãããžãŒã«ãããã·ãªã³ãŒã³ãã§ãŒã³ã«
æ°ŽååãåŒãå¯ããããããšã§ãã¬ã³ãºã®äžå¿éšãã衚é¢ãŸã§
1æ¥äžãããããä¿æããçŽ æãå®çŸ*4â
é·ãã·ãªã³ãŒã³ãã§ãŒã³
é·ãã·ãªã³ãŒã³ãã§ãŒã³ãé žçŽ ééæ§ãæå€§åããã·ãªã³ãŒã³éãæžããããšã§ãåœç€Ÿã®ã·ãªã³ãŒã³ã¬ã³ãºã®äžã§1çªã®ããããããå®çŸããŸãã*5ïŒåŒŸæ§ç0.4MPaïŒâ
芪氎æ§ã¢ãŒã â
ã·ãªã³ãŒã³ãã§ãŒã³ã«æ°ŽååãåŒãå¯ããã¬ã³ãºå šäœã«ãã£ããæ°Žåãä¿æããŸãã*6â
èªç¶ãªãããããããŒãã*4
衚é¢ã³ãŒãã£ã³ã°ãäžèŠãªæœ€æ»å€ã¯å ããŠããŸããã
-
ããããããŒãã¬ã³ãºééã®2å
æ°Žåéããã£ããä¿æããã¬ã³ãºã®äžå¿ãã衚é¢ãŸã§æœ€ããç¶ããŸãã
-
99.5%
è£ çšåŸã§ã99%以äžã®æ°Žåãä¿æããããšãå ±åãããŠããŸãã*7
-
100%
è§èãæ¶è²»ããé žçŽ éãå±ããŸãã*8
ãµã¹ããããªãã£ãžã®åãçµã¿
ã¯ãŒããŒããžã§ã³ã®ã³ã³ã¿ã¯ãã¬ã³ãºâ»9ã¯
ããã©ã¹ããã¯ãã¥ãŒãã©ã«â»10ã
ç§ãã¡ã¯ãµã¹ããããªãã£ãžã®åãçµã¿ã®äžç°ãšããŠãããç°å¢ã«ããããäºæ¥éå¶ã远æ±ããŠããŸããåææã®èª¿éãã補åèšèšã補é ã»å å·¥ããã»ã¹ã®èŠçŽããããã«ã¯å»æ£ç©ã®åæžã»ååã»ãªãã»ããã«è³ããŸã§ãããããé¢ã§æ¹åãé²ããŠããŸãããããã®åãçµã¿ã¯ãã¹ãŠã人ã ãšå°çã®å¥ãããªæªæ¥ãèŠæ®ãããã®ã§ãã
- â»1 ç±³åœã¯ãŒããŒããžã§ã³èª¿ã¹ïŒ2020幎ïŒè±åœã§ã®1é±éè£ çšãã¹ãã®çµæããã€ãã€Â® ãã«ããã©ãŒã«ã«ãäœéšãã104åãåçã
- â»2 2025幎12æçŸåš
- â»3 ç±³åœã¯ãŒããŒããžã§ã³èª¿ã¹ïŒ2021幎ïŒç±³åœã®5æœèšã§ã®2é±éè£ çšãã¹ãã®çµæããã€ãã€Â® ãã«ããã©ãŒã«ã«ãäœéšãã58åãåçã
- â»4 ã¢ã¯ã¢ãã©ãŒã ® ãã¯ãããžãŒã§å«æ°Žç54ïŒ
- â»5 Compared among CooperVision 1day silicon hydrogel contact lenses.CVI data on file.
- â»6 Aquaform® Technology: Why Material Science Matters. CVI data on file 2022.
- â»7 Absolute moisture retention 99.7%, relative moisture retention 99.6%. CVI data on file, 2024. CVI data on file 2019. Multi-visit study to assess handling performance and dehydration characteristics for 4 DD CLs in 20 CL wearers.
- â»8 During daily wear. Brennan NA. Beyond Flux: Total Corneal Oxygen Consumption as an Index of Corneal Oxygenation During Contact Lens Wear. Optom Vis Sci. 2005;82(6):467-472.
- â»9 ã³ã³ã¿ã¯ãã¬ã³ãºãšã¯ãæ¥æ¬ã«ãããŠã¯ãŒããŒããžã§ã³ãè²©å£²ã»æµéãã補åãæããŸãã
- â»10 ãã©ã¹ããã¯ãã¥ãŒãã©ã«ãšã¯ãäŒæ¥ãå人ããäžå®æéå ã«è²©å£²ãããã©ã¹ããã¯ãã¥ãŒãã©ã«ãªè£œåã«å«ãŸãããã©ã¹ããã¯éãšåéã®ãã©ã¹ããã¯ãååããªãµã€ã¯ã«ããããšã§ãã©ã¹ããã¯ãããããªã³ãã®äžéšãçžæ®ºããããšãç®æãæŠå¿µã§ããã¯ãŒããŒããžã§ã³ã¯ã補åã®ãã©ã¹ããã¯äœ¿çšéã«çžåœããã¯ã¬ãžããã宿çã«ãã©ã¹ããã¯ãã³ã¯ããè³Œå ¥ããŠããããã©ã¹ããã¯ãã³ã¯ã®åçµã¿ãéããŠãã©ã¹ããã¯ãã¥ãŒãã©ã«ãéæããŠããŸããã³ã³ã¿ã¯ãã¬ã³ãºã®ãã©ã¹ããã¯äœ¿çšéã¯ã空ã±ãŒã¹ãã¬ã³ãºãããã±ãŒãžã«äœ¿çšãããã©ãããŒããæ¥çå€ã溶å€ïŒã€ã³ã¯ãªã©ïŒã®ãã©ã¹ããã¯ã®ééã§æ±ºãŸããŸãã

















